SCHMIDT Technology

Thermal flow sensor for uni- or bi-directional measurement of the flow rate of air and gases with simultaneous detection of the flow direction in an explosive atmosphere (Zone 2).

Extremely compact, because electronics are integrated into the sensor tube. Sensor element in the chamber head and protected against mechanical stress. Linear analog output for measured value edition, two switching outputs to output the flow direction and the signal of threshold.

Configurable on site via built-in RS232 interface using a programming kit for Windows™ PCs.

By installation into a measuring tube suitable for the measurement of the standard volume flow or mass flow.

Hotline
+49 (0) 77 24 / 899 - 170

Application Examples

  • Laminar flow monitoring in cleanrooms
  • Monitoring of the overflow
  • Cooling air monitoring
  • Flow measurement in test benches
  • Mass and volume flow measurement
  • Use in potentially explosive atmospheres caused by gases (zone 2)

Calibration

We accompany our sensors over their entire life cycle in our

HinweisCalibration Service Center