SCHMIDT Technology
  Description Article-Number
Basic sensor SCHMIDT® Flow Sensor SS 20.600; output signal 4 … 20 mA and 0 … 10 V; impulse output, incl. Pressure-tight stainless steel compression fitting 524 600 - A B C D E F G H PP
  Options
Mechanical type Sensor length 120 mm   1                
Sensor length 250 mm   2                
Sensor length 400 mm   3                
Sensor length 600 mm   4                
Special sensor lengths:  __________ mm
(> 120 mm ... 1,000 mm, 10-mm-steps)
  8                
Remote version (selectable sensor length:
(120 / 250 / 400 / 600 mm)
cable length: ____ m (1 … 10 m; 1-m-steps)
  9                
Pressure-tight compression fitting, stainless steel G ½     1              
Pressure-tight compression fitting, stainless steel R ½ (P T)     2              
Measuring ranges and adjustment Measuring range 0 … 10 m/s       1            
Measuring range 0 … 20 m/s       2            
Measuring range 0 … 60 m/s       3            
Measuring range 0 … 90 m/s       4            
Measuring range 0 … 140 m/s       5            
Measuring range 0 … 220 m/s       6            
Special measuring range (10 … 220 m/s) in 0,1 m/s steps: _____ , _____ m/s       9            
Standard adjustment         1          
Standard adjustment with certificate         0          
High-precision adjustment incl. ISO calibration certificate         2          
Standard adjustment check with conversion factor for methane 1         3          
Standard adjustment with conversion factor for biogas (60 % methane, 40 % CO2) 1         4          
Standard adjustment with conversion factor for CO2 1         5          
Standard adjustment with correction to natural gas with 88 % CH4 1         7          
Standard adjustment with conversion factor for special gases and mixture 1         9          
Impulse output Standard 100 Hz (= final value of measuring range wN)           1        
Special impulse output: 1 … 100 Hz           9        
1 impulse / 1 m3 for pipe diameter (round) _____ mm           2        
1 impulse / 0,1 m3 for pipe diameter (round) _____ mm           3        
1 impulse / 0,01 m3 for pipe diameter (round) _____ mm           4        
Additional outputs Without communication module             1      
Communication module for DeviceNet, Profi-BUS DP-V0             2      
Protection type ATEX Without ATEX design               1    
ATEX design 2               2    
Protection type Standard application                 1  
Grease-free and for O2 > 21 % 1                 2  
Overpressure Operating pressure DD: 00 (atmospheric) … 16 bar                   00 … 16
Operating pressure DD: 17 … 40 bar1                   17 … 40

 

  1. Not available with the option special lengths
  2. Application of sensor in ATEX area only with original connection cable 524 921 or 524 942 and without communication modules